<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <title>DSpace Собрание:</title>
  <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11512" />
  <subtitle />
  <id>http://dspace.puet.edu.ua:80/handle/123456789/11512</id>
  <updated>2026-04-14T18:38:32Z</updated>
  <dc:date>2026-04-14T18:38:32Z</dc:date>
  <entry>
    <title>Розробка електротехнічної системи уф-дезінфекції води для рециркуляційних аквакультурних установок</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/16175" />
    <author>
      <name>Cеменов, Анатолій</name>
    </author>
    <author>
      <name>Семенова, Наталія</name>
    </author>
    <author>
      <name>Semenov, A. O.</name>
    </author>
    <author>
      <name>Semenova, N. V.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/16175</id>
    <updated>2026-03-03T20:50:48Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Название: Розробка електротехнічної системи уф-дезінфекції води для рециркуляційних аквакультурних установок; Development of an electrotechnical system for uv water disinfection in recirculating aquaculture systems
Авторы: Cеменов, Анатолій; Семенова, Наталія; Semenov, A. O.; Semenova, N. V.
Аннотация: Одним із ключових завдань функціонування установок замкненого водопостачання (УЗВ) для вирощування риби є забезпечення мікробіологічної безпеки води. Серед відомих методів дезінфекції найбільш поширеними є озонування та ультрафіолетове (УФ) випромінювання, а також їхні комбінації. Проте застосування озону супроводжується низкою обмежень: токсичністю для гідробіонтів, утворенням побічних продуктів та зниженням розчиненого кисню у воді, що знижує його придатність для УЗВ. У роботі представлено результати досліджень з розробки та впровадження електротехнічної системи ультрафіолетового знезараження води, яка працює за принципом проточного опромінення із попереднім фільтруванням. Як джерело бактерицидного випромінювання застосовано лампи низького тиску з максимумом на довжині хвилі 254 нм. Експериментальні дослідження на аквафермі з вирощування осетрових показали, що використання УФ-установки сумарною потужністю 850 Вт&#xD;
(10 ламп низького тиску) забезпечує стабільний бактерицидний потік на рівні 220 Вт/м² та ефективну інактивацію мікроорганізмів у системах об’ємом до 80 м³. Протягом усього періоду спостережень загальне мікробне число, загальні коліформи та E.coli не перевищували допустимих норм, а випадків бактеріальних та грибкових захворювань риби не було зафіксовано. Розроблена електротехнічна система знезараження води дозволяє підвищити надійність і біологічну безпеку функціонування УЗВ без використання озону, є енергоефективною та придатною для масштабування у промислових аквакультурних господарствах.; One of the key tasks in the operation of recirculating aquaculture systems (RAS) for fish farming is to ensure the microbiological safety of water. Among the known disinfection methods, the most widely used are ozonation, ultraviolet (UV) irradiation, and their combinations. However, the application of ozone is accompanied by several limitations: toxicity to aquatic organisms, formation of harmful by-products, and reduction of dissolved oxygen in water, which makes it less suitable for RAS. This study presents the results of research on the development and implementation of an electrotechnical UV water disinfection system operating on the principle of flow-through irradiation with preliminary filtration. As a source of bactericidal radiation, low-pressure lamps with a maximum emission wavelength of 254 nm were used. Experimental studies conducted at a sturgeon aquafarm demonstrated that the use of a UV unit with a total power of 850 W (10 low-pressure lamps) provides a stable bactericidal flux of 220 W/m² and ensures effective inactivation of microorganisms in systems with a water volume of 100 m³. Throughout the observation period, the total microbial count, total coliforms, and E. coli did not exceed permissible limits, and no cases of bacterial or fungal diseases in fish were recorded.&#xD;
The developed electrotechnical water disinfection system improves the reliability and biological safety of RAS operation without the use of ozone, is energy-efficient, and can be scaled for industrial aquaculture facilities.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Раціональні режими роботи насосних електроприводів за умов частотного та комбінованого регулювання</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/16169" />
    <author>
      <name>Семенов, Анатолій</name>
    </author>
    <author>
      <name>Семенова, Наталія</name>
    </author>
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Semenova, Nataliia</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/16169</id>
    <updated>2026-03-03T20:50:25Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Название: Раціональні режими роботи насосних електроприводів за умов частотного та комбінованого регулювання; Rational operating modes of pump electric drives under frequency and combined control
Авторы: Семенов, Анатолій; Семенова, Наталія; Semenov, Anatolii; Semenova, Nataliia
Аннотация: У роботі досліджено раціональні режими роботи насосних електроприводів систем водопостачання в умовах змінного добового водоспоживання з метою підвищення їх енергетичної ефективності. Актуальність дослідження зумовлена значною часткою насосних установок у загальному балансі електроспоживання промислового та комунального секторів, зростанням вартості енергоресурсів і необхідністю впровадження енергоощадних технологій.&#xD;
Показано, що традиційні способи регулювання подачі рідини не забезпечують належної енергоефективності та стабільності роботи в умовах нерівномірного водоспоживання. На основі аналізу сучасних наукових публікацій встановлено, що більшість досліджень ґрунтується на ідеалізованих моделях і не враховує реальні умови експлуатації насосних станцій, зокрема добові коливання навантаження та втрати в гідротранспортній системі. У роботі виконано порівняльну оцінку ефективності нерегульованого, частотного та комбінованого способів керування насосними електроприводами.&#xD;
Методика дослідження включала інженерні розрахунки з використанням законів гідродинамічної подібності та експериментальне узагальнення добових режимів роботи насосної станції. Зазначено, що математичне моделювання застосовувалося для попередньої оцінки тенденцій зміни енергоспоживання і не претендує на абсолютну точність через неврахування гідравлічних втрат. Встановлено, що застосування частотного регулювання дозволяє знизити середню питому енергоємність до 0,30–0,33 кВт·год/м³, а мінімальні значення (0,12–0,13 кВт·год/м³) досягаються в години пікового водоспоживання. Найвищу ефективність продемонструвала комбінована схема керування, за якої середня питома енергоємність зменшується до 0,13–0,15 кВт·год/м³, що відповідає економії електроенергії 55–60% порівняно з нерегульованим режимом. Отримані результати підтверджують доцільність використання частотного та комбінованого регулювання насосних електроприводів і можуть бути застосовані для попереднього техніко-економічного обґрунтування модернізації насосних станцій. Разом із тим результати не призначені для прямого прогнозування економічного ефекту без урахування конкретних параметрів гідротранспортної системи та складу обладнання.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Digital integration of vacuum switching devices in electrical power network systems</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/16155" />
    <author>
      <name>Semenov, А</name>
    </author>
    <author>
      <name>Bychkov, Y.</name>
    </author>
    <author>
      <name>Kharak, R.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/16155</id>
    <updated>2026-03-03T20:50:39Z</updated>
    <published>2026-01-19T00:00:00Z</published>
    <summary type="text">Название: Digital integration of vacuum switching devices in electrical power network systems
Авторы: Semenov, А; Bychkov, Y.; Kharak, R.
Аннотация: The paper addresses the implementation of vacuum switching devices in combination with digital monitoring and diagnostic systems as an integral component of modern high-voltage electrical networks. Particular attention &#xD;
is focused on the analysis of electrophysical switching processes in a vacuum environment, the structural features of contact assemblies, and the possibilities for integrating circuit breakers into hierarchical control systems in accordance with the Smart Grid concept. The principles of vacuum arc operation, the characteristics of dielectric strength recovery in the inter-contact gap, and the influence of contact materials on the stability of switching regimes are summarized. The architecture of modern monitoring systems based on the IEC 61850 standard is considered, including the use of electrical and thermal sensors, microprocessor-based controllers, and integration at the SCADA/industrial automation level. It is shown that the combination of vacuum circuit breakers with digital control tools ensures a reduction in fault localization time, an increase in equipment availability, and a decrease in operational risks. A generalized structural model of the “vacuum circuit breaker – digital control” system is proposed, suitable for application in 6–35 kV networks and, prospectively, in substations of the 110–220 kV class.</summary>
    <dc:date>2026-01-19T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Раціональні режими роботи насосних електроприводів за умов частотного та комбінованого регулювання</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/16153" />
    <author>
      <name>Cеменов, А. О.</name>
    </author>
    <author>
      <name>Семенова, Н. В.</name>
    </author>
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Semenova, Nataliia</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/16153</id>
    <updated>2026-03-03T20:50:46Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Название: Раціональні режими роботи насосних електроприводів за умов частотного та комбінованого регулювання; Rational operating modes of pump electric drives under frequency and combined control
Авторы: Cеменов, А. О.; Семенова, Н. В.; Semenov, Anatolii; Semenova, Nataliia
Аннотация: У роботі досліджено раціональні режими роботи насосних електроприводів систем водопостачання в умовах змінного добового водоспоживання з метою підвищення їх енергетичної ефективності. Актуальність дослідження зумовлена значною часткою насосних установок у загальному балансі електроспоживання промислового та комунального секторів, зростанням вартості енергоресурсів і необхідністю впровадження енергоощадних технологій.&#xD;
Показано, що традиційні способи регулювання подачі рідини не забезпечують належної енергоефективності та стабільності роботи в умовах нерівномірного водоспоживання. На основі аналізу сучасних наукових публікацій встановлено, що більшість досліджень ґрунтується на ідеалізованих моделях і не враховує реальні умови експлуатації насосних станцій, зокрема добові коливання навантаження та втрати в гідротранспортній системі. У роботі виконано порівняльну оцінку ефективності нерегульованого, частотного та комбінованого способів керування насосними електроприводами.&#xD;
Методика дослідження включала інженерні розрахунки з використанням законів гідродинамічної подібності&#xD;
та експериментальне узагальнення добових режимів роботи насосної станції. Зазначено, що математичне моделювання застосовувалося для попередньої оцінки тенденцій зміни енергоспоживання і не претендує на абсолютну точність через неврахування гідравлічних втрат. Встановлено, що застосування частотного регулювання дозволяє знизити середню питому енергоємність до 0,30–0,33 кВт·год/м³, а мінімальні значення (0,12–0,13 кВт·год/м³) досягаються в години пікового водоспоживання. Найвищу ефективність продемонструвала комбінована схема керування, за якої середня питома енергоємність зменшується до 0,13–0,15 кВт·год/м³, що відповідає економії електроенергії 55–60% порівняно з нерегульованим режимом. Отримані результати підтверджують доцільність використання частотного та комбінованого регулювання насосних електроприводів і можуть бути застосовані для попереднього техніко-економічного обґрунтування модернізації насосних станцій. Разом із тим результати не призначені для прямого прогнозування економічного ефекту без урахування конкретних параметрів гідротранспортної системи та складу обладнання.; The problem of improving the energy efficiency of pumping installations in water supply systems remains one of the key challenges of modern energy engineering, as such installations account for a significant share of electricity consumption in industrial and municipal sectors. Rising energy prices, increasing environmental requirements, and the need to implement energy-saving technologies determine the relevance of research in this area. Analysis shows that most pumping stations in Ukraine still operate with unregulated induction motors using direct-on-line starting, which results in excessive electricity consumption, hydraulic shocks, high starting currents, and accelerated equipment wear. Traditional flow control methods, such as throttling and stepwise control, do not meet current energy efficiency and operational stability requirements under conditions of variable water demand. Purpose. The purpose of this study is to improve the efficiency of pump electric drives by substantiating rational operating modes through the application of frequency-controlled and combined control schemes under variable daily water consumption. Methodology. A comprehensive approach was employed, including engineering calculations of energy consumption, mathematical modeling based on the laws of hydrodynamic similarity, and experimental generalization of daily operating modes of pumping stations. It is emphasized that the mathematical modeling was used for a preliminary assessment of energy consumption trends and does not claim absolute accuracy due to the neglect of hydraulic losses in the pump and the hydraulic transport system. Scientific novelty. For the first time, rational daily operating modes of pump electric drives under variable water consumption conditions have been comparatively substantiated by integrating frequency-controlled and combined control schemes, allowing a quantitative assessment of their energy efficiency and operational advantages. Results. It was established that the application of frequency control reduces the average specific energy consumption to 0.30–0.33 kWh/m³, with minimum values of 0.12–0.13 kWh/m³ achieved during peak water consumption periods. The combined control scheme, involving two pumping units operating in frequency-controlled and fixed-speed modes, demonstrated the highest efficiency, with an average specific energy consumption of 0.13–0.15 kWh/m³, corresponding to electricity savings of 55–60% compared to the unregulated operating mode. Practical value. The obtained results can be used for preliminary technical and economic justification of modernization projects for pumping stations in municipal and agro-industrial sectors. At the same time, the results are not intended for direct prediction of economic effects without considering the specific parameters of the hydraulic transport system and equipment configuration.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Оптимізація електроприводів насосних агрегатів систем водопостачання на основі частотного регулювання</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/15825" />
    <author>
      <name>Cеменов, Анатолій Олексійович</name>
    </author>
    <author>
      <name>Скрипник, Вячеслав Олександрович</name>
    </author>
    <author>
      <name>Сахно, Тамара Вікторівна</name>
    </author>
    <author>
      <name>Бут, Андрій Григорович</name>
    </author>
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Skrypnyk, Viacheslav</name>
    </author>
    <author>
      <name>Sakhno, Tamara</name>
    </author>
    <author>
      <name>But, Andrii</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/15825</id>
    <updated>2026-03-03T20:44:10Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Название: Оптимізація електроприводів насосних агрегатів систем водопостачання на основі частотного регулювання; Optimization of pump unit electric drives in water supply systems based on  frequency control
Авторы: Cеменов, Анатолій Олексійович; Скрипник, Вячеслав Олександрович; Сахно, Тамара Вікторівна; Бут, Андрій Григорович; Semenov, Anatolii; Skrypnyk, Viacheslav; Sakhno, Tamara; But, Andrii
Аннотация: У статті досліджено питання підвищення енергоефективності насосних станцій шляхом модернізації їх електроприводів із застосуванням &#xD;
частотного та комбінованого регулювання. Актуальність проблеми обумовлена зростанням вартості енергоресурсів, підвищенням вимог до &#xD;
ефективності технологічних процесів, а також значною часткою електроенергії, що споживається насосним обладнанням у промисловості та &#xD;
комунальному господарстві. Обґрунтовано доцільність переходу від нерегульованих асинхронних електродвигунів до частотно-регульованих &#xD;
систем керування, що дозволяє адаптувати роботу насосів до змін водоспоживання, зменшити енергоспоживання, покращити стабільність &#xD;
тиску в мережі, продовжити термін служби обладнання, а також знизити витрати на технічне обслуговування та ремонт. У роботі наведено &#xD;
результати математичного моделювання режимів роботи насосної станції з урахуванням законів подібності та проведено аналіз добових &#xD;
графіків роботи для різних режимів керування. Підтверджено зниження питомої енергоємності при частотному регулюванні до &#xD;
0,32 кВт·год/м³, а також ефективність комбінованої схеми керування на базі трьох насосних агрегатів, один з яких працює з частотним &#xD;
перетворювачем. Такий підхід забезпечив мінімальний показник питомої енергоємності – 0,06 кВт·год/м³, що відповідає до 60 % &#xD;
енергозбереження порівняно з традиційними схемами без регулювання. Дослідження підтвердило, що впровадження частотного та &#xD;
комбінованого регулювання дає змогу значно підвищити енергоефективність насосних установок в умовах змінного навантаження, зменшити &#xD;
гідравлічні удари, знизити пускові струми та підвищити надійність обладнання. Розроблені рекомендації можуть бути використані під час &#xD;
модернізації існуючих насосних станцій, планування інвестиційних проектів у сфері водопостачання, а також при впровадженні &#xD;
автоматизованих систем керування для промислових і муніципальних об’єктів.; The article examines the issue of improving the energy efficiency of pumping stations through the modernization of their electric drives by implementing frequency and combined control methods. The relevance of the problem is determined by the rising cost of energy resources, the increasing requirements for the efficiency of technological processes, and the significant share of electricity consumed by pumping equipment in industry and public utilities. The feasibility of transitioning from non-adjustable asynchronous electric motors to frequency-controlled systems is substantiated, enabling pumps to adapt to changes in water consumption, reduce energy consumption, improve network pressure stability, extend equipment service life, and lower maintenance and repair costs. The paper presents the results of mathematical modeling of pumping station operating modes based on similarity laws and an analysis of daily operating graphs for various control modes. It confirms a reduction in specific energy consumption with frequency control to 0.32 kWh/m³, as well as the effectiveness of a combined control scheme using three pump units, one of which operates with a frequency converter. This approach achieved a minimum specific energy consumption of 0.06 kWh/m³, corresponding to up to 60 % energy savings compared to traditional non-regulated schemes. The study confirmed that the implementation of frequency and combined control makes it possible to significantly increase the energy efficiency of pumping units under variable load conditions, reduce hydraulic shocks, lower starting currents, and improve equipment reliability. The developed recommendations can be applied in the modernization of existing pumping stations, the planning of investment projects in the water supply sector, and the implementation of automated control systems for industrial and municipal facilities.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Підвищення надійності розподільчого пристрою 220 кВ на тепловій електростанції шляхом модернізації</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/15748" />
    <author>
      <name>Цицак, Т. П.</name>
    </author>
    <author>
      <name>Семенова, Н. В.</name>
    </author>
    <author>
      <name>Семенов, А. О.</name>
    </author>
    <author>
      <name>Tsytsak, T. P.</name>
    </author>
    <author>
      <name>Semenova, N. V.</name>
    </author>
    <author>
      <name>Semenov, A. O.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/15748</id>
    <updated>2026-03-03T20:36:18Z</updated>
    <published>2025-12-01T00:00:00Z</published>
    <summary type="text">Название: Підвищення надійності розподільчого пристрою 220 кВ на тепловій електростанції шляхом модернізації; Enhancing the reliability of the 220 kv switchyard at a thermal power plant through modernization
Авторы: Цицак, Т. П.; Семенова, Н. В.; Семенов, А. О.; Tsytsak, T. P.; Semenova, N. V.; Semenov, A. O.
Аннотация: Статтю присвячено розробленню проєкту відновлення електрообладнання відкритого розподільчого пристрою ВРП) 220 кВ теплової електричної станції з урахуванням вимог інтеграції до синхронної зони ENTSO-E та критерію N-1. На підставі аналізу технічного стану встановлено значну зношеність комутаційних апаратів і вимірювальних трансформаторів, що спричиняє зростання аварійності та експлуатаційних витрат. Методично робота спирається на нормативну базу (IEC, ДСТУ, ПУЕ, рекомендації ENTSO-E), розрахунок струмів короткого замикання за підходом IEC 60909, перевірку термічної та електродинамічної стійкості, інженерні розрахунки заземлення та грозозахисту, а також техніко-економічну оцінку. Запропоновано заміну повітряних вимикачів на SF6-вимикачі HPL-245B1, застосування роз’єднувачів SGF-245, трансформаторів струму IMB-245 і напруги CPA-245, а також ОПН PEXLIM; передбачено цифровізацію РЗА (IEC 61850) та інтеграцію у SCADA/EMS. Результати розрахунків підтверджують відповідність вибраного обладнання вимогам за I2t та ударним струмам; забезпечено опір заземлення ≤ 0,5 Ом та суцільне покриття зон грозозахисту. Економічні розрахунки демонструють річний ефект 2,03 млн грн і термін окупності ≈ 3,25 року, що свідчить про інвестиційну привабливість модернізації. Наукова новизна полягає у комплексному поєднанні технічної, релейно-захисної, екологічної та економічної складових реконструкції ВРП 220 кВ; практична цінність – у відтворюваності підходу для модернізації аналогічних підстанцій і ТЕС України.; The article is devoted to the development of a project for the restoration of the electrical equipment of the 220 kV open switchyard (OSY) of the Thermal Power Plant, taking into account the requirements of integration into the ENTSO-E synchronous zone and the N-1 criterion. Based on the analysis of the technical condition, significant wear of switching devices and instrument transformers was identified, which leads to increased failure rates and operating costs. Methodologically, the study relies on the regulatory framework (IEC, DSTU, PUE, ENTSO-E recommendations), calculation of short-circuit currents according to IEC 60909, verification of thermal and electrodynamic stability, engineering calculations of grounding and lightning protection, as well as a techno-economic assessment. The proposed solutions include the replacement of air circuit breakers with SF₆ circuit breakers HPL-245B1, the use of SGF-245 disconnectors, IMB245 current transformers and CPA-245 voltage transformers, as well as PEXLIM surge arresters; digitalization of protection and control (IEC 61850) and integration into SCADA/EMS are also foreseen. The calculation results confirm the compliance of the selected equipment with I²t and short-circuit withstand requirements; grounding resistance ≤ 0.5 Ω and complete lightning protection coverage are ensured. Economic calculations demonstrate an annual effect of UAH 2.03 million and a payback period of ≈3.25 years, which indicates the investment attractiveness of modernization. The scientific novelty lies in the comprehensive integration of technical, protection and control, environmental, and economic components of the 220 kV switchyard reconstruction; the practical value lies in the reproducibility of the approach for the modernization of similar substations and TPPs in Ukraine.</summary>
    <dc:date>2025-12-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Раціональні режими роботи насосних електроприводів: дослідження ефективності частотного та комбінованого регулювання</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/15683" />
    <author>
      <name>Cеменов, Анатолій</name>
    </author>
    <author>
      <name>Семенова, Наталія</name>
    </author>
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Semenova, Nataliia</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/15683</id>
    <updated>2026-03-03T20:03:49Z</updated>
    <published>2025-01-01T00:00:00Z</published>
    <summary type="text">Название: Раціональні режими роботи насосних електроприводів: дослідження ефективності частотного та комбінованого регулювання; Rational operating modes of pump electric drives: efficiency study of frequency and combined control
Авторы: Cеменов, Анатолій; Семенова, Наталія; Semenov, Anatolii; Semenova, Nataliia
Аннотация: У статті розглянуто проблему підвищення енергоефективності насосних установок систем водопостачання, які є найбільшими споживачами електроенергії в промисловості та комунальному господарстві. Актуальність дослідження зумовлена зростанням вартості енергоресурсів, необхідністю зниження викидів парникових газів і тенденціями до впровадження енергоощадних технологій. Показано, що більшість систем водопостачання в Україні з використанням насосних агрегатів працюють на базі нерегульованих асинхронних двигунів із прямим пуском від мережі, що призводить до підвищених пускових струмів, гідравлічних ударів, перевитрат електроенергії та до скорочення ресурсу обладнання. Традиційні методи регулювання подачі (дроселювання, ступінчасте керування) не відповідають сучасним вимогам енергоефективності. Перспективним напрямом є використання частотно-регульованих електроприводів (ЧРП), які забезпечують адаптацію продуктивності насосів до реального водоспоживання. Виконане математичне моделювання на основі законів подібності підтвердило зниження питомої енергоємності до 0,32 кВт·год/м³. Результати експериментальних вимірювань показали, що мінімальне значення цього показника досягалося в години пікового водоспоживання – 0,122 кВт·год/м³, тоді як у нічний час він зростав у кілька разів. Досліджено також комбіновану схему регулювання на базі двох насосних агрегатів, один з яких працює під керуванням ЧРП, а інший – у фіксованому режимі. Такий підхід дозволив знизити середню питому енергоємність до 0,12 кВт·год/м³, що відповідає енергозбереженню до 60 %. Отримані результати підтверджують ефективність застосування частотного та комбінованого регулювання, підвищують надійність і довговічність обладнання та створюють передумови для цифровізації систем водопостачання в різних сферах діяльності.; The problem of improving the energy efficiency of pumping installations in water supply systems is one of the key tasks of modern energy engineering, since these installations are among the largest electricity consumers in industry and municipal services. Rising energy costs and global trends toward the implementation of energy-saving technologies determine the relevance of research in this field. Analysis shows that most pumping stations in Ukraine operate on the basis of unregulated induction motors with direct-on-line starting, which leads to excessive electricity consumption, hydraulic shocks, increased starting currents, and a reduction in equipment lifetime. Traditional flow control methods (throttling, step control) do not meet modern energy efficiency requirements and need to be replaced. Purpose. The research aims to improve the efficiency of pump electric drives by optimizing operating modes through the application of frequency and combined control. Methodology. A comprehensive approach was applied, including analytical calculations of energy consumption, mathematical modeling based on similarity laws, and experimental verification of the results on operating installations. Energy and techno-economic indicators were used to evaluate efficiency. Scientific novelty. For the first time, rational operating modes of pump electric drives under variable water consumption conditions have been substantiated using a combined control scheme that integrates frequency-controlled and unregulated operation. It has been proven that such a scheme ensures: reduction of specific energy consumption to 0.09–0.12 kWh/m³ (which is 60% lower compared to traditional modes); improvement of system pressure stability and reduction of dynamic loads; creation of technical prerequisites for the integration of pumping stations into digital monitoring and control systems. Results. It was found that the use of frequency control reduces the specific energy consumption to 0.32 kWh/m³, and during peak water consumption hours – to 0.122 kWh/m³. The combined scheme with two pumping units demonstrated even higher efficiency, with an average specific energy consumption of 0.12 kWh/m³, which ensures up to 60% energy savings compared to traditional systems. Practical value. The developed recommendations can be applied in the modernization of pumping stations in municipal services and the agro-industrial sector. This will reduce operating costs, improve pressure stability, extend equipment lifetime, and create prerequisites for the digitalization of water supply systems.</summary>
    <dc:date>2025-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Методика оцінювання розрахункових навантажень у системах елекропостачання мережі 0,38 кв</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/15367" />
    <author>
      <name>Semenova, N.</name>
    </author>
    <author>
      <name>Semenov, A.</name>
    </author>
    <author>
      <name>But, A.</name>
    </author>
    <author>
      <name>Семенова, Н. В.</name>
    </author>
    <author>
      <name>Семенов, А. О.</name>
    </author>
    <author>
      <name>Бут, А. Г.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/15367</id>
    <updated>2026-03-03T20:55:50Z</updated>
    <published>2025-08-13T00:00:00Z</published>
    <summary type="text">Название: Методика оцінювання розрахункових навантажень у системах елекропостачання мережі 0,38 кв
Авторы: Semenova, N.; Semenov, A.; But, A.; Семенова, Н. В.; Семенов, А. О.; Бут, А. Г.
Аннотация: У статті представлено методику оцінювання розрахункових навантажень у дільницях мережі напругою 0,38 кВ. Обґрунтовано необхідність адаптації розрахункових методів. Запропоновано алгоритм обчислення максимального навантаження із застосуванням уточнених коефіцієнтів попиту, одночасності та завантаження. Проведено класифікацію типових дільниць мережі та визначено характерні параметри навантажень для кожного типу. Здійснена апробація методики в умовах реконструкції сільської мережі.; The article presents a methodology for assessing design loads in sections of 0.38 kV power distribution networks. The need for adapting calculation methods is substantiated. An algorithm for calculating the maximum load is proposed, incorporating refined demand, coincidence, and loading factors. A classification of typical network sections is provided, along with characteristic load parameters for each type. The methodology has been tested under conditions of rural network reconstruction.</summary>
    <dc:date>2025-08-13T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Інноваційні стратегії та підходи до адаптації українських бізнес-моделей і менеджменту якості в умовах невизначеності</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/15145" />
    <author>
      <name>Горячова, Олена Олександрівна</name>
    </author>
    <author>
      <name>Педченко, Геннадій Володимирович</name>
    </author>
    <author>
      <name>Пиріг, Ярослав Борисович</name>
    </author>
    <author>
      <name>Лавецький, Микита Владиславович</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/15145</id>
    <updated>2026-03-03T20:54:18Z</updated>
    <published>2024-01-01T00:00:00Z</published>
    <summary type="text">Название: Інноваційні стратегії та підходи до адаптації українських бізнес-моделей і менеджменту якості в умовах невизначеності
Авторы: Горячова, Олена Олександрівна; Педченко, Геннадій Володимирович; Пиріг, Ярослав Борисович; Лавецький, Микита Владиславович
Аннотация: Під час війни українські бізнес-моделі зазнали стратегічних змін, адаптуючись до умов невизначеності та високого рівня ризикованості, що включало оптимізацію витрат, нові логістичні потоки, гібридний формат роботи, економію енергоресурсів, безпекоорієнтований менеджмент, трансформацію менеджменту якості та впровадження інновацій для збереження конкурентоспроможності. Метою статті є вивчення інноваційних стратегій і підходів до адаптації українських бізнес-моделей і систем управління якістю в умовах невизначеності, зокрема під час війни,&#xD;
для забезпечення їхньої стійкості та конкурентоспроможності. У статті підкреслено, що під час війни українські компанії змушені шукати&#xD;
нові джерела прибутку, застосовуючи стратегії диверсифікації, впровадження інноваційних підходів, диджиталізації, гнучких моделей управління, короткострокового планування, перерозподілу ролей та обов’язків, а також нових технологій для забезпечення конкурентоспроможності й ефективності операцій. Окреслено особливості менеджменту якості у воєнний період і відмічено, що компанії стикаються з перебоями в постачанні, проблемами з виробництвом, змінами в асортименті, психологічними труднощами працівників, економічними викликами, необхідністю підтримки високих стандартів якості та комунікації з клієнтами, що вимагає впровадження альтернативних стратегій, таких як пошук нових постачальників, створення запасів сировини, впровадження резервних джерел енергії, перепідготовка персоналу, розробка нових продуктів, психологічна підтримка працівників, оптимізація витрат, інвестиції в ефективні технології, впровадження систем управління якістю, регулярні аудити, інформування клієнтів та використання цифрових технологій. Встановлено, що українські компанії змушені швидко адаптуватися до нових умов, використовуючи стратегії диверсифікації постачальників, упровадження цифрових технологій, гнучкість у виробництві та асортименті продукції, підтримку працівників та забезпечення їхньої безпеки, а також постійний моніторинг ринкових умов та конкурентів.</summary>
    <dc:date>2024-01-01T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Результати визначення вливу вологовмісту на потік речовини в м'ясі під комбінованою дією теплового потоку і електричного струму</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/13827" />
    <author>
      <name>Скрипник, В. О.</name>
    </author>
    <author>
      <name>Семенов, А. О.</name>
    </author>
    <author>
      <name>Бичков, Я. М.</name>
    </author>
    <author>
      <name>Фарісєєв, А. Г.</name>
    </author>
    <author>
      <name>Skrypnyk, V.</name>
    </author>
    <author>
      <name>Semenov, A.</name>
    </author>
    <author>
      <name>Bychkov, Y.</name>
    </author>
    <author>
      <name>Farisieiev, A.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/13827</id>
    <updated>2026-03-03T20:40:46Z</updated>
    <published>2024-05-20T00:00:00Z</published>
    <summary type="text">Название: Результати визначення вливу вологовмісту на потік речовини в м'ясі під комбінованою дією теплового потоку і електричного струму; Results оf Determining the Influence of Moisture Content on the Flow of Substances in Meat Under the Combined Action of Heat Flow and Electric Current
Авторы: Скрипник, В. О.; Семенов, А. О.; Бичков, Я. М.; Фарісєєв, А. Г.; Skrypnyk, V.; Semenov, A.; Bychkov, Y.; Farisieiev, A.
Аннотация: The article investigates the patterns of substance flow occurrence in pork meat under the influence of electric current, heat flow from a heater, and their combined action. It has been established that the moisture content of the meat has a significant and nonlinear impact on the volume of substances transferred in the meat under the influence of electric current and heat flow. Analytical dependencies are proposed to determine quantitative parameters taking into account moisture content, meat area and thickness, potential difference, heat flow magnitude, and applied excess pressure.; У статті досліджено закономірності виникнення потоку речовини в м’ясі свинини під впливом електричного струму, теплового потоку від нагрівача та їх комбінованої дії. Встановлено, що вологовміст м’яса має істотний і нелінійний вплив на об’єм речовини, що переноситься в м’ясі під впливом електричного струму та теплового потоку. Запропоновані аналітичні залежності для визначення кількісних параметрів з урахуванням вологовмісту, площі та товщини м’яса, різниці потенціалів, величини теплового потоку та прикладеного надлишкового тиску.</summary>
    <dc:date>2024-05-20T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Ефективність регульованого електроприводу в насосних установках водозабезпечення</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/13682" />
    <author>
      <name>Семенов, А. О.</name>
    </author>
    <author>
      <name>Харак, Р. М.</name>
    </author>
    <author>
      <name>Бичков, Я. М.</name>
    </author>
    <author>
      <name>Скрипник, В. О.</name>
    </author>
    <author>
      <name>Semenov, A.</name>
    </author>
    <author>
      <name>Kharak, R.</name>
    </author>
    <author>
      <name>Bychkov, Y.</name>
    </author>
    <author>
      <name>Skrypnyk, V.</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/13682</id>
    <updated>2026-03-03T20:33:22Z</updated>
    <published>2024-04-10T00:00:00Z</published>
    <summary type="text">Название: Ефективність регульованого електроприводу в насосних установках водозабезпечення; The efficiency of the controlled electric drive in water supply pump installations
Авторы: Семенов, А. О.; Харак, Р. М.; Бичков, Я. М.; Скрипник, В. О.; Semenov, A.; Kharak, R.; Bychkov, Y.; Skrypnyk, V.
Аннотация: The efficiency of the controlled electric drive in pump installations for water supply systems has been studied.&#xD;
The impact of pump speed regulation on system productivity and reliability has been analyzed. The research results indicate a reduction in electricity consumption and optimization of pump installation operation when using a controlled electric drive, which opens up prospects for efficient resource utilization in modern water supply and drainage systems; Досліджено ефективність регульованого електроприводу в насосних установках для систем водозабезпечення. Аналізовано вплив регулювання швидкості обертання насосів на продуктивність та надійність системи. Результати досліджень вказують на зниження споживання електроенергії та оптимізацію роботи насосних установок при використанні регульованого електроприводу, що відкриває перспективи для ефективного використання ресурсів у сучасних системах водопостачання та водовідведення.</summary>
    <dc:date>2024-04-10T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Assessment of the danger of using ultraviolet lamps in electrical systems</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/13369" />
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Popov, Stanislav</name>
    </author>
    <author>
      <name>Yakhin, Serhii</name>
    </author>
    <author>
      <name>Yeleussinov, Bauyrzhan</name>
    </author>
    <author>
      <name>Sakhno, Tamara</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/13369</id>
    <updated>2026-03-03T20:37:47Z</updated>
    <published>2024-01-19T00:00:00Z</published>
    <summary type="text">Название: Assessment of the danger of using ultraviolet lamps in electrical systems
Авторы: Semenov, Anatolii; Popov, Stanislav; Yakhin, Serhii; Yeleussinov, Bauyrzhan; Sakhno, Tamara
Аннотация: To determine the photobiological safety of UV lamps, the following measurements were carried out: spectral irradiance, total actinic irradiance in the wavelength range of 200-400 nm, and irradiance in the UVA range (320-400 nm). These parameters were measured using the optical radiation system OST-300. The photobiological safety of LUF 40-1, LE 15 lamps and their radiation risk group are established in accordance with EN 62471. The levels of UV radiation generated by LE 15 low pressure discharge lamps at a distance of 0.25 m belong to the high risk group &#xD;
(GR3), and LUF 40-1 - in the group of insignificant risk (GR1). Calculations and recommendations on safe radiation doses when using lamps in electrotechnical systems of photobiological influence are given.</summary>
    <dc:date>2024-01-19T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Визначення гомогенності кормів для тварин з використанням феромагнітних мікротрейсерів</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11918" />
    <author>
      <name>Сахно, Тамара Вікторівна</name>
    </author>
    <author>
      <name>Семенов, Анатолій Олексійович</name>
    </author>
    <author>
      <name>Сахно, Юрій Едуардович</name>
    </author>
    <author>
      <name>Барашков, Микола Миколайович</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11918</id>
    <updated>2026-03-03T20:25:26Z</updated>
    <published>2022-05-12T00:00:00Z</published>
    <summary type="text">Название: Визначення гомогенності кормів для тварин з використанням феромагнітних мікротрейсерів
Авторы: Сахно, Тамара Вікторівна; Семенов, Анатолій Олексійович; Сахно, Юрій Едуардович; Барашков, Микола Миколайович
Аннотация: Зі збільшенням продуктивності тварин підвищуються вимоги до однорідності кормів. У країнах з розвиненим тваринництвом комбікорм з однорідністю 95 % вважають відмінним, 90 % – добрим, 80 % і менше – не прийнятним. Вимога до однорідності комбікормів за останні роки зросла у зв'язку з ускладненням їх рецептури, що включає все більше компонентів, при цьому не відіграє особливої ролі: чи компоненти потрапляють у корми безпосередньо в змішувач або з преміксами. У статті обґрунтовано доцільність використання феромагнітних мікротрейсерів для оцінки гомогенності кормів з метою підвищення їх якості й отримання міжнародного сертифіката GMP+ (В1 та В2). Феромагнітні мікротрейсери є частинками заліза або нержавіючої сталі, на поверхні яких адсорбовані харчові барвники різних кольорів. При складанні вітамінних, мінеральних або лікарських преміксів мікротрейсер використовується для позначення їхньої присутності в готових кормах, а також для ідентифікації кормових добавок та кормів, що містять такі добавки. Дослідження проводились за допомогою обертального детектора з використанням сертифікованих виробником мікротрейсерів Microtracer F (розмір частинок яких від 125 до 400 мікрон). Аналіз якості процесу змішування відповідно до нової версії стандарту GMP+ВА2 проводився для працюючого вітчизняного комбікормового заводу. Було відібрано 20 зразків і здійснено статистичну оцінку відповідно до розподілу Пуассона. Розрахована ймовірність однорідності змішування комбікормів виявилася гарною (р = 5,1 %), що відповідає вимогам міжнародному стандарту GMP+B1. Такий комбікорм є безпечним для тварин і надає гарантії споживачеві щодо виробництва, обробки, торгівлі, зберігання та транспортування кормових інгредієнтів і кормів для тварин не лише в Україні, а й у більшості європейських країн.</summary>
    <dc:date>2022-05-12T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Bactericidal Disinfection of Activated Carbon from Aerobic Microorganisms, Yeasts and Molds</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11893" />
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Sakhno, Tamara</name>
    </author>
    <author>
      <name>Hmelnitska, Yevgenia</name>
    </author>
    <author>
      <name>Semenova, Nataliia</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11893</id>
    <updated>2026-03-03T20:25:11Z</updated>
    <published>2022-03-29T00:00:00Z</published>
    <summary type="text">Название: Bactericidal Disinfection of Activated Carbon from Aerobic Microorganisms, Yeasts and Molds
Авторы: Semenov, Anatolii; Sakhno, Tamara; Hmelnitska, Yevgenia; Semenova, Nataliia</summary>
    <dc:date>2022-03-29T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Перевірка якості змішування кормів та преміксів за допомогою феромагнітних мікротрейсерів</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11651" />
    <author>
      <name>Сахно, Тамара Вікторівна</name>
    </author>
    <author>
      <name>Семенов, Анатолій Олексійович</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11651</id>
    <updated>2026-03-03T20:35:29Z</updated>
    <published>2022-02-04T00:00:00Z</published>
    <summary type="text">Название: Перевірка якості змішування кормів та преміксів за допомогою феромагнітних мікротрейсерів
Авторы: Сахно, Тамара Вікторівна; Семенов, Анатолій Олексійович</summary>
    <dc:date>2022-02-04T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Забійні якості свиней різних генотипів</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11625" />
    <author>
      <name>Бірта, Габріелла Олександрівна</name>
    </author>
    <author>
      <name>Бургу, Юрій Георгійович</name>
    </author>
    <author>
      <name>Флока, Людмила Валеріївна</name>
    </author>
    <author>
      <name>Хмельницька, Євгенія Вікторівна</name>
    </author>
    <author>
      <name>Горячова, Олена Олександрівна</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11625</id>
    <updated>2026-03-03T20:33:28Z</updated>
    <published>2022-01-28T00:00:00Z</published>
    <summary type="text">Название: Забійні якості свиней різних генотипів
Авторы: Бірта, Габріелла Олександрівна; Бургу, Юрій Георгійович; Флока, Людмила Валеріївна; Хмельницька, Євгенія Вікторівна; Горячова, Олена Олександрівна
Аннотация: В статті досліджено забійні та м’ясо-сальні якості тварин різних генотипів. Було визначено наступні показники: передзабійна маса; забійна маса; забійний вихід; довжина напівтуші; товщина шпику; площа «м’язового вічка»; вихід м’яса і сала в туші, морфологічний склад туш, масу м’язової тканини. На основі одержаних експериментальних даних проведено дисперсійний аналіз впливу форм годівлі на забійні якості свиней. В середньому по досліду загальна дисперсія, що показує загальну мінливість ознаки при забої свиней живою масою 100 кг, коливалась від 0,93 у свиней миргородської породи до 1,01 у полтавської м’ясної породи. Найбільшою частка впливу форми годівлі на забійний вихід спостерігалась у свиней м’ясних генотипів, зокрема у полтавської м’ясної 84,9-88,8% та червоної білопоясої породи свиней 86,4-83,6%. Результати забою засвідчили перевагу м'ясних генотипів над представниками сальних і м'ясо-сальних порід за показниками забійного виходу, довжини напівтуші, товщини шпику та маси окосту. В сучасних умовах виробництва свинини відгодівля тварин потребує врахування певних проблем, пов’язаних із впливом умов утримання, повноцінної годівлі, статі та результативності виробництва – середньодобові прирости, товщину шпику, витрати корму на одиницю продукції. Відгодівлю свиней різної статі необхідно організовувати відповідно до їх потреби у поживних речовинах</summary>
    <dc:date>2022-01-28T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Забійні якості свиней різних генотипів</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11624" />
    <author>
      <name>Бірта, Габріелла Олександрівна</name>
    </author>
    <author>
      <name>Бургу, Юрій Георгійович</name>
    </author>
    <author>
      <name>Флока, Людмила Валеріївна</name>
    </author>
    <author>
      <name>Хмельницька, Євгенія Вікторівна</name>
    </author>
    <author>
      <name>Горячова, Олена Олександрівна</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11624</id>
    <updated>2026-03-03T20:32:58Z</updated>
    <published>2022-01-28T00:00:00Z</published>
    <summary type="text">Название: Забійні якості свиней різних генотипів
Авторы: Бірта, Габріелла Олександрівна; Бургу, Юрій Георгійович; Флока, Людмила Валеріївна; Хмельницька, Євгенія Вікторівна; Горячова, Олена Олександрівна
Аннотация: В статті досліджено забійні та м’ясо-сальні якості тварин різних генотипів. Було визначено наступні показники: передзабійна маса; забійна маса; забійний вихід; довжина напівтуші; товщина шпику; площа «м’язового вічка»; вихід м’яса і сала в туші, морфологічний склад туш, масу м’язової тканини. На основі одержаних експериментальних даних проведено дисперсійний аналіз впливу форм годівлі на забійні якості свиней. В середньому по досліду загальна дисперсія, що показує загальну мінливість ознаки при забої свиней живою масою 100 кг, коливалась від 0,93 у свиней миргородської породи до 1,01 у полтавської м’ясної породи. Найбільшою частка впливу форми годівлі на забійний вихід спостерігалась у свиней м’ясних генотипів, зокрема у полтавської м’ясної 84,9-88,8% та червоної білопоясої породи свиней 86,4-83,6%. Результати забою засвідчили перевагу м'ясних генотипів над представниками сальних і м'ясо-сальних порід за показниками забійного виходу, довжини напівтуші, товщини шпику та маси окосту. В сучасних умовах виробництва свинини відгодівля тварин потребує врахування певних проблем, пов’язаних із впливом умов утримання, повноцінної годівлі, статі та результативності виробництва – середньодобові прирости, товщину шпику, витрати корму на одиницю продукції. Відгодівлю свиней різної статі необхідно організовувати відповідно до їх потреби у поживних речовинах.</summary>
    <dc:date>2022-01-28T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Вплив УФ-випромінювання на біологічні властивості та водопоглинання при передпосівному опроміненні насіння ріпаку озимого</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11623" />
    <author>
      <name>Семенов, Анатолій</name>
    </author>
    <author>
      <name>Сахно, Тамара</name>
    </author>
    <author>
      <name>Семенова, Наталія</name>
    </author>
    <author>
      <name>Ляшенко, Віктор</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11623</id>
    <updated>2026-03-03T20:33:13Z</updated>
    <published>2022-01-27T00:00:00Z</published>
    <summary type="text">Название: Вплив УФ-випромінювання на біологічні властивості та водопоглинання при передпосівному опроміненні насіння ріпаку озимого
Авторы: Семенов, Анатолій; Сахно, Тамара; Семенова, Наталія; Ляшенко, Віктор
Аннотация: At present, the studies of physiological and biochemical processes affecting seed germination, plant growth and their resistance to abiotic stresses are becoming topical. This stipulates the necessity of improving seed sowing qualities by improving the techniques of pre-sowing seed treatment using physical methods among which pre-sowing crop seed treatment with ultra-violet irradiation is considered the most effective. Owing to the impact of UV irradiation energy, metabolic processes between the cell and the environment are activated, ensuring quicker access of water and nutrients to the germ strengthening breathing and growth processes and creating favorable conditions for further plant growth and development. The influence of UV radiation of C region (200–280 nm) of Sherpa winter variety rapeseeds in pre-sowing treatment was investigated. In the work, the treatment was conducted with ZW20D15W ultraviolet lamps applying the following doses: 50, 120, 250, 500, 1000 and 3000 J/m2. Measuring UVirradiation doses was made by “Tensor-31” radiometer produced at the scientific and production enterprise “Tensor”, Ukraine. It has been found that UV radiation has a positive effect on the sowing qualities of rapeseed when irradiated with doses of 120 J/m2: the germinating energy increased by 15 %, and the germinating capacity – by 11% as compared with the control samples. At irradiation doses of 250, 500, 1,000 and 3,000 J/m2, the decrease in the seeds sowing qualities is observed. The main parameters of hydration kinetic values were determined: moisture content and hydration rate. The study results have shown that hydro-priming increases the kinetics of water absorption, moreover, the rate of hydration increased sharply in the initial phase and gradually and slowly decreased in the middle and final phases of the hydration procedure. UV-irradiated seeds at a dose of 120 J/m2 showed faster penetration of water into the seeds and more effective tissue hydration, positively affecting the sowing qualities and biometrics in comparison with higher doses. It has been suggested that UV irradiation of rapeseeds in pre-sowing treatment can reduce excessive imbibition damage, since the germination potential decreases. Key words: UV-C irradiation, winter rapeseeds, germinating energy and germinating</summary>
    <dc:date>2022-01-27T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Фізіологічна реакція рослин сортів гречки посівної Fagopyrum esculentum Moench за умови різних режимів гідропраймінгу на ранніх етапах онтогенезу</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11546" />
    <author>
      <name>Ляшенко, Віктор Васильович</name>
    </author>
    <author>
      <name>Сахно, Тамара Вікторівна</name>
    </author>
    <author>
      <name>Тригуб, Олег Володимирович</name>
    </author>
    <author>
      <name>Семенов, Анатолій Олексійович</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11546</id>
    <updated>2026-03-03T20:21:58Z</updated>
    <published>2023-02-07T00:00:00Z</published>
    <summary type="text">Название: Фізіологічна реакція рослин сортів гречки посівної Fagopyrum esculentum Moench за умови різних режимів гідропраймінгу на ранніх етапах онтогенезу
Авторы: Ляшенко, Віктор Васильович; Сахно, Тамара Вікторівна; Тригуб, Олег Володимирович; Семенов, Анатолій Олексійович
Аннотация: У сучасних умовах необхідності збільшення обсягів виробництва сільськогосподарської продукції доцільним може бути застосування технологій праймінгу для підготовки насіннєвого матеріалу до сівби. Ми дослідили фізіологічні реакції рослин сортів гречки посівної Fagopyrum esculentum Moench при різних режимах гідропраймінгу на ранніх етапах онтогенезу. Електропровідність насіння гречки посівної визначали за виходом електролітів у розчин протягом 2–24 год. гідратації насіння за температури 20 оС за допомогою мультиметра AD8000 ADWA. Лабораторні дослідження проведені у трьох біологічних і п՚яти аналітичних повторах. У лабораторному експерименті енергія проростання оцінювалася на 3-й день, а схожість – на 7-й день. Дані оброблялися загальноприйнятими статистичними методами аналізу. Виявлено, що у гречки сортів Рожевоквіта 2-19 і П-454 електропровідність ексудатів з насіння збільшилася за 300 хв. на 52 і 78 %, відповідно. За умови гідропраймінгу енергія росту насіння максимально збільшується для сорту Рожевоквіта 2-19 після 24 годин на 46 %, а для сорту П-454 – після 10 годин праймінгу на 70 %. Визначено, що для сортів з низькою енергією росту Рожевоквіта 2-19 та П-454 гідропраймування збільшило енергію проростання за 10-и годинний праймінг у 3,5 раза та 6 разів, відповідно. Стосовно сорту гречки П-338 доцільно відзначити зниження енергії проростання після праймінгу майже на 40 %. Отримані результати розкривають окремі сторони механізму взаємодії гідропраймінгу з рослинними об՚єктами, що дозволяють більш обґрунтовано використовувати режими гідропраймінгу для вирощування різних сортів гречки посівної.</summary>
    <dc:date>2023-02-07T00:00:00Z</dc:date>
  </entry>
  <entry>
    <title>Ultraviolet disinfection of water in recirculating aquaculture system: a case study at sturgeon caviar fish farm</title>
    <link rel="alternate" href="http://dspace.puet.edu.ua:80/handle/123456789/11545" />
    <author>
      <name>Semenov, Anatolii</name>
    </author>
    <author>
      <name>Semenova, Kateryna</name>
    </author>
    <id>http://dspace.puet.edu.ua:80/handle/123456789/11545</id>
    <updated>2026-03-03T20:22:28Z</updated>
    <published>2023-02-07T00:00:00Z</published>
    <summary type="text">Название: Ultraviolet disinfection of water in recirculating aquaculture system: a case study at sturgeon caviar fish farm
Авторы: Semenov, Anatolii; Semenova, Kateryna
Аннотация: In this report, we present a practical example of ultraviolet (UV) water disinfection in an aquaculture facility for sturgeon caviar production. Among the methods of water disinfection in recirculating aquaculture systems, the technical approaches using ozonation or ultraviolet radiation in combination with other methods are the most effective. However, improper use of ozonation can result in excessive ozone concentrations that can cause serious harm to fish and be harmful to the environment and personnel. Therefore, we describe an example of a reagent-free ultraviolet water disinfection system. Preliminary results show that filtration followed by ultraviolet irradiation inactivates microorganisms in fish tank water. Total microbial count, total coliform bacteria, and E. coli (CFU/m3) did not exceed the permissible values. The described UV system provides an irradiance of 180 W/m2. For a pool with a water volume of 300 m3, bacteriological purity of the water was achieved with 480 W of UV-light.</summary>
    <dc:date>2023-02-07T00:00:00Z</dc:date>
  </entry>
</feed>

