Електронний архів Полтавського університету економіки і торгівлі >
Навчально-науковий інститут денної освіти >
Кафедра товарознавства, біотехнології, експертизи та митної справи >
Статті (ННІДО ТБЕМС) >
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс:
http://dspace.puet.edu.ua/handle/123456789/8977
|
Название: | ASSESSING THE QUALITY OF HOMOGENEITY OF PET FOOD USING FERROMAGNETIC MICRO TRACERS |
Другие названия: | ОЦІНКА ЯКОСТІ ГОМОГЕННОСТІ КОРМІВ ДЛЯ ДОМАШНІХ ТВАРИН З ВИКОРИСТАННЯМ ФЕРРОМАГНІТНИХ МІКРОТРЕЙСЕРІВ |
Авторы: | Sakhno, Tamara Semenov, Anatolii Barashkov, Nikolay |
Ключевые слова: | mixing compound feed food quality microtracers markers pet food the Rotary Detector |
Дата публикации: | 15-Июл-2020 |
Аннотация: | Obtaining highly homogeneous mixtures is an urgent task in many areas of feed production, as it is associated with the need for even distribution of particularly important and valuable components. Manufacturers of animal feed are using several different
methods for performing homogeneity studies to check their mixer performance.
This paper is devoted to the use of nontraditional markers such as ferromagnetic Microtracers to evaluate the homogeneity
of the final feed. Microtracers have successfully been used in a mixer testing program in the USA since 1985 and in Europe since
2006. They represent a major improvement over traditional analytical procedures for evaluation of mixer performance involving the
use of cobalt or manganese salts. The authors described the quantitative results of determination and identification of Microtracers
in two sets of 20 samples of pet food manufactured by Kormotech LLC with using a proprietary Rotary Detector procedure developed
by Micro-Tracers Inc (San Francisco, California). It was shown that analysis of 150 g samples at level of Microtracer addition
of 20 g per metric ton of pet food allowed a magnetic retrieval of the number of ferromagnetic particles from 61 to 101 which was
sufficient for application of Poisson and Chi-squared statistics. The obtained results from two tests performed with different time of
mixing were interpreted in accordance with the requirements of the GMP + BA2 standard. It was determined that mixing within 3
min leads to the marginal mixing with the calculated probability value of 1.12%. The prolonged mixing within 4 min leads to complete
mixing with the calculated probability value of 5.93%. The use of ferromagnetic Microtracers in a mixer testing program is
justified for such tasks as comparison of mixers with each other, as well as identifying the changes in the technical characteristics of the mixers and their performance occurring during their exploitation. In addition, using microtracers can quickly determine the
quality of the mixing equipment when it is purchased. |
Описание: | ASSESSING THE QUALITY OF HOMOGENEITY OF PET
FOOD USING FERROMAGNETIC MICRO TRACERS / Grain Products and Mixed Fodder’s. 2020. Vol.20, I.2(78). |
URI: | http://dspace.puet.edu.ua/handle/123456789/8977 |
ISSN: | 2313-478X (print); 2411-3921 (online) |
Располагается в коллекциях: | Статті (ННІДО ТБЕМС)
|
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.
|